The following is a list of the States that can be filtered for the Doors amd Devices.
- AutoOpen Enabled: The door/device is in an auto-open state due to a schedule
- AutoOpen Disabled: The door/device is not currently in an auto-open state due to a schedule.
- AutoOpen Override Enabled: The door/device has an active override or toggle during an auto-open schedule.
- AutoOpen Override Disabled: The door/device does not have an active override or toggle during an auto-open schedule.
- Force Close Enabled: The door/device has been sent a Force Close command and is currently in this state.
- Force Close Disabled:The door/device has not been sent a Force Close command and is not currently in this state.
- Force Open Enabled: The door/device has been sent a Force Open command and is currently in this state.
- Force Open Disabled: The door/device has not been sent a Force Open command and is not currently in this state.
- Open (Lock): The door/device is currently in the unlocked/activated state.
- Close (Lock): The door/device is currently in the locked/deactivated state.
- Open (DPS): The door/device input for the Door Position Sensor (A) is reporting as open or no continuity on the input.
- Close (DPS): The door/device input for the Door Position Sensor (A) is reporting as closed or continuity on the input.
- Door Propped Alarm: The door/device input for the Door Position Sensor has detected being open longer that the Door Prop setting in the Device configuration.
- Door Propped Alarm Clear: The door/device input for the Door Position Sensor has not detected being open longer that the Door Prop setting in the Device configuration.
- Door Forced Alarm: The door/device has detected the door/device is currently in the Door Forced Alarm condition..
- Door Forced Alarm Clear: The door/device has detected the door/device is not currently in the Door Forced Alarm condition.
- Circuit Breaker On: A flood of event logging (40 events in 30 seconds) occurred on either input A or B (DPS or REX) on the door/device and this state is currently active
- Circuit Breaker Off: A flood of event logging (40 events in 30 seconds) has not occurred on either input A or B (DPS or REX) on the door/device and this state is not currently active
- Partial Connectivity Detected: The controller for the door/device is currently in a partial connectivity state.
- Partial Connectivity Cleared: The controller for the door/device is not currently in a partial connectivity state.