When using System Event rules, a Trigger event must be selected. When this Trigger event occurs on any of the selected Source Devices, the Action event configured will occur.
Below is a list of the available Trigger Events along with a description of what each Trigger means.
- On Open - The door position sensor (DPS) is open
- On Close - The door position sensor (DPS) is closed
- On Propped - The door is held or propped open longer than the prop Trigger period
- On Forced - The door is opened without a valid credential read or Request to Exit (REX) input
- On Prop Cleared - The door position sensor was closed after the prop Trigger was activated
- All Prop Cleared - All door-propped alarms have been cleared
- On Rex Open - Request to Exit (REX) input is activated (unlocked). For example, connecting NO on the REX to the PDK REX input (B)
- On Rex Close - Request to Exit (REX) input closed is deactivated (locked). For example, connecting NC on the REX to the PDK REX input (B)
- On Credentials Input - Trigger the event on ANY credential input, either valid or invalid
- On Credentials Not Found - Credential input at the reader that is not recognized or not programmed in the system
- On Comm Loss - Device communication that is lost
- On Comm Loss Cleared - Communication to the connection has been re-established
- On Any Duress - When a Duress PIN is entered
- On Input Power Loss - When primary input power is lost/disconnected
- On Input Power Recovery - When primary input power is restored
- On Overcurrent Detected - When excess or higher than intended current is detected on the indicated Controller
- On Overcurrent Cleared - When standard or intended current is detected on the indicated Controller, the detection event is cleared
- On Underpowered Input Detected - When insufficient current is detected on the indicated Controller
- On Underpowered Input Alarm Cleared - When sufficient current is detected on the indicated Controller, the underpowered detection event is cleared
- On Low Power Mode On - When low power mode is detected
- On Low Power Mode Off - When low power mode is not detected
- On Battery Connect - When expected battery power is detected
- On Battery Disconnect - When battery power is lost
- On Battery Level Change - When battery level on a Red Wireless Lock has changed
- On Circuit Breaker On - A 'Circuit Breaker' event occurred. This is a flood of event logging (40 events in 30 seconds) occurring on either input A or B (DPS or REX), which disables the input for 30 minutes
- On Circuit Breaker Off - A 'Circuit Breaker' event ended
- On Partial Connectivity Detected - The controller is not responding, but contact with the WiMAC radio is established
- On Partial Connectivity Cleared - Communication between the WiMAC radio and controller is restored
- On Jammed - When the Red Wireless Deadbolt is jammed
- On Jammed Cleared - When the Red Wireless Deadbolt is no longer jammed